Javelin™ is designed to withstand the extreme environments and stresses that are inherent in military applications and industrial uses. A rugged, single output power supply available in single phase – with or without a fan–or 3-phase inputs. Outputs of 2, 3.3, 5, 12, 15, 24, 28, 32, 36 & 48 Vdc are available at up to 5,400 W.
Input Voltages:
- Javelin I: 85 – 254 Vac (1Φ), 85-380 Vdc
- Javelin II: 85 – 254 Vac (1Φ), 85-380 Vdc
- Javelin III: 85 – 254 Vac (1 or 3Φ),85-380 Vdc
Output Power:
- Javelin I: Single Output, Up to 1,800 W
- Javelin II: Single Output, Up to 1,800 W
- Javelin III: Single Output, Up to 5,400 W
Cooling:
- Javelin I: Internal Fans
- Javelin II: No Fan
- Javelin III: Internal Fans
Operating Temperature:
- Full power to 55°C; Half power at 70°C -20°C standard; -40 and -55°C optional
Power Factor Correction:
- 0.99 at 115 Vac; 0.95 at 230 Vac
Dimensions:
- Javelin I: 10.75″ L x 7.0″ W x 4.9″ H(273.05 x 177.8 x 124.46 mm)
- Javelin II: 9.5″ L x 7.0″ W x 4.9″ H(241.3 x 177.8 x 124.46 mm)
- Javelin III:13.0″ L x 16.0″ W x 7.0″ H(330.2 x 406.4 x 177.8 mm)
- MIL-STD-704E AC Input
- MIL-STD-461E EMI: CE101, 102; RE101, 102
- Shock and vibration to MIL-STD-167-1, MIL-STD-810 & MIL-S-901
- PFC threshold: Less than 3% THD; 3-Phase configuration nearly sinusoidal input current
- Ride-through (holdup) time:>20 msec at 1,200 W load
- Case-to-case paralleling capability
- Inhibit & enable inputs, DC OK, automatic remote sense
- Soft start for limiting inrush current; AC Power OK status signal
- Output OCP, OVP, & OTP
- Optional conformal coating
Mechanical drawings are included in the data sheets