Features
- Selectable 0-5 V and 0-10 V signal levels
- Isolated programming and monitoring of U, I and status signals
- Prevents problems with earth loops and CM-voltages
- Factory installed or external module
Functionalities
- Pin compatible with Delta Elektronika programming connector
- ISO AMP Card fits in SM800, SM1500, SM3000 and SM6000
- ISO AMP Module for an external solution
- Internal interface cards are calibrated
Specifications
- Programming and monitoring offset: +/- 60 µV typical
- Full scale error: 0.1% calibrated
- Non-linearity: 0.01% typical
- TC: -65 ppm / °C
- Common mode rejection: 80 dB @ 50 Hz
Standards
- Generic Emission: EN 61326-1 (class B equipment, for use in domestic establishment)
- Generic Immunity: EN 61326-1 (equipment for use in industrial and domestic establishment)
- Insulation test voltage: 4250 V DC
- Protection class: IP20
Dimensions and weight
- Width: 79 mm
- Height: 50 mm
- Depth: 124 mm
- Weight: 0.4 kg
Data sheets | ||
---|---|---|
Datasheet isolation amplifier |