Advanced Energy’s Excelsys CoolX1800 series of high density, multiple-output modular power supplies is ideal for medical, life science, industrial, and harsh-environmental applications. The power supplies support series and parallel configurations for ultimate flexibility and simultaneous O/P DC power.
- 1800 W in a compact package
- Industrial and medical safety approvals
- 24 W-standby power
- PMBus™ for digital communications and control
- Up to 12 isolated outputs (1850 VAC)
Overview
- Access incredible power via a compact supply. The modular Excelsys CoolX®1800 offers 1800 W in a 267 x 127 x 41 mm package (approximately 50% more power than the industry standard). Outputs can be parallel connected for higher currents and series connected for higher voltages (up to 348 VDC).
The series is available in two base models. The CX18S has the IEC60950 (second edition) certification for industrial applications and will comply with the upcoming IEC62368-1 standard. The CX18M carries IEC60601-1 (third edition) and the IEC60601-1-2 (fourth edition, EMC) standards for medical applications. Both can be populated with up to six CoolMods, providing up to 12 isolated DC outputs that range from 1 to 58 V.
Benefits
- High Power Density: 1800 W in a 267 x 127 x 41 mm package
- Full Safety Agency Approvals: See Technical Specs for details
- Intelligent Digital Power: Access maximum flexibility with analog and digital control (PMBus™)
- User- and Field-Configurable: Configure outputs to setpoint voltages; connect in parallel/series for higher output current and/or voltages
- High Reliability and Efficiency: Help ensure quality, reliability, and a low total cost of ownership
Features
- 93% efficiency
- Five-year warranty
- MTBF figures of > 200000
- Safety approved to 5000 m altitude
Electrical
Input Voltage Range | 85 to 264 VAC |
Input Current | up to 25 A (je nach Modell) |
Output Power | Up to 1800 W (je nach Modell) |
Output Voltage | 1 to 348 (je nach Modell) |
Ripple and Noise | 1% of nominal |
Environmental
Operating Temperature Range |
-40 to 70 °C |
Storage Temperature Range |
-40 to 85°C |
Relative Humidity | 5% to 95% |
Mechanical
L x W x H | 267 mm x 127 mm x 41 mm (10.5 in x 5 in x 1U) |
Weight | 1.6 kgs |
Control
Digital and analog
powerMods
CoolMods | CmA,CmB,CmC,CmD |
High Power Modules (3 Slot) | CmE, CmF |
Dual Output Modules (1 Slot) | CmG (version 1 and 2), CmH (version 1 and 2) |
Wide Trim Modules (1 Slot) | CmM, CmN, CmP, CmQ |
Certifications and Standards
CX18S – Industrial | IEC60950 (second edition)/ IEC62368-1 |
CX18M – Medical | IEC60601-1 (third edition) / IEC60601-1-2 (fourth edition, EMC) |